2-Channel Traffic Inductive Loop Vehicle Detector Daul Control


Application

  • DLD-600 is used for wherever vehicles have to be detected

  • For monitoring and safe-guarding access ways or counting vehicles.

  • The output signal can be used for controlling door and gate drive mechanisms, operating barriers, controlling traffic light systems or activating card dispensers in parking lots.

  • DLD-600 connects two loop.


To  download the manual please click here


Technical Data

  • Type:DLD-600(double channel)

  • Operating voltages:12VDC,24VDC, 110VAC ,220VAC

  • Power consumption: < 5W

  • Output:Relay output

  • Frequency range: 20kHz to 170kHz (4 grades adjustable)

  • Reaction time: 20 ms

  • Sensitivity: 10 grades adjustable

  • Loop inductance: Ideal 100~300µH (include connecting wiring)

  • Max 50µH~1000µH (include connecting wiring)

  • Loop conn. Wiring: Max.100m, twisted at least 20 times per meter, Total resistance <10 Ohm

  • Operating temp.: -30oC to +75oC

  • Storage temp.: -40oC to +85oC

  • Relative humidity: <=95%

  • Connection: 11-pin socket

  • Shell: PC + ABS engineering plastics

  • Installation: DIN rail

  • Dimensions: 110x60x100 mm (LxWxH)

  • Net Weight: 400g (include socket)


Principle

It is based on a change in the inductance within the loop which is caused by the metallic components of passing

vehicles. The changes are picked up and evaluated by a microprocessor.


Tune

The tuning process is automatically. It can tune with the connected loop automatically when detector started or reset.

The tuning range is from 50µH to 1000µH, and such wide tuning range ensures low requirements for the loop and wiring.

Once tuned, any inductance changes will feedback to the compensation circuit in detector to ensure normal work.


Adjustable sensitivity

The sensitivity relays on some factors, such as loop size, loop turns, wiring length, whether or not there are metals under the loop

and  so on. When in low sensitivity, the detector will detect vehicles with high chassis or trailers correctly, but can’t detect cars,

bicycles and other small metals. The sensitivity adjust button is the rotary encoder switch on the panel, “0” with low sensitivity

and “9” with high sensitivity.  A switch on left is corresponding to loop A, while B on right is corresponding to loop B. While using,

adjust the sensitivity from low to high, to find a proper one for steady state.


Reaction time

Its definition is that the time starting from the metal enters into the loop and ending when the detector gives indication signals.

It is specialized and optimized for parking lots.


Frequency adjustment


There are four frequencies to choose for users. Open the panel, pull out the circuit board, and dial SW1 (channel A) or SW2

(channel B) with small screwdriver. You can change the frequencies to avoid interferes from the environments or the two adjacent

inductive loops.


Output mode of relay

Every channel has two relay outputs in our detectors. There are two relays A1 and A2 with channel A. And there are two  relays B1

and B2 with channel B. Relay A1 and B1 are existing output (on when metals on the loop and off when metals leaving). Relay A2

and B2 are multifunctional output set by the three bit code switch on the left of the panel. Operate as follows:

 

Working state

After connecting with the power supply the detector can calibrate itself automatically and the two red lights are on at the same

time,which will continue for 2s. During the calibration, the red light always lasts two seconds. (Note: there should be no cars

parked in loop).  After the success of calibration, the two panel indicator goes out. In normal working condition, when the car

passed the loop,the panel on the corresponding indicator light and a corresponding relay action (refer to "relay output");

if the calibration process  was not detected the loop, the corresponding indicator lights will be kept flashing.


Loop installation sketch map