商品情報にスキップ
1 18

Rhombus Access Control System

Wiring-free Wireless 1K User 125KHz EM/ID Standalone Access Control+Strick lock

Wiring-free Wireless 1K User 125KHz EM/ID Standalone Access Control+Strick lock

通常価格 $66.95 USD
通常価格 セール価格 $66.95 USD
セール 売り切れ
Colour

 

Product advantages

The control system with no wire connection is adopted for the set of the entrance guard controller and the door button, which avoids complex sequences of wiring and punching.


Installation precautions

The wireless door guard device and the wireless door switch cannot be installed on metal door or metal surface wall, otherwise, it will affect the performance of the product.

 

The overall features of the wireless entrance guard:

1. You can set 1000 cards, with 1000 standard user capacity.

2. The ways of opening the door: induction card, password, induction card and password, induction card or password.

3. The wireless entrance guard device is powered by battery without wiring connection. The operation and usage is simple and clear.lt is flexible to add or remove a card. The card can be deleted offline.

4. The code - drawing is used for switch coding, which is flexible and simple and can effectively prevent the interference of adjacent entrance guard device.

 

The technical parameters of the wireless entrance guard device:

  • The wireless entrance guard device is powered by four AAA dry batteries (1.5V).
  • Standby current: 28mA Action current: 38mA
  • Storage capacity:1000 standard users (ID card) output time: 1 S to 1 0 S (adjustable)
  • User card type: 125KHZ or EM EM compatible card
  • The password of opening the door: one public password
  • Read card distance: 10 to 70 (mm) Wireless transmitting distance: greater than or equal to 8 m
  • Battery life: over 6 months (less than 100 times per day)
  • Wireless transmission frequency: 315 MHZ working environment temperature: -10 °C 70°C
  • Material: Plastic
  • External size: 139 x 75 x 25 ( mm )

 

Wireless exit switch parameters:

  • Powered by: 1 x 12V 23A Battery (included)
  • Operating Frequency: 315MHz±2MHz
  • Material: Plastic
  • Size:83x40x15(mm)

 

Power parameters

  • Input Voltage:AC100-240V 50/60Hz
  • Output voltage:DC12V/5A
  • Wireless Receive Control Output
  • Wireless reception doorbell
  • Size:145x58*32(mm)

Strike Lock

Model:15AO

  • Lock Size: 150Lmmx39.5Wmmx28Hmm
  • Bolt structure: Stainless Steel
  • Voltage: DC12V
  • Current: 450mA(CEN-15AO)
  • Feature: Fail Secure(CEN-15AO)
  • Suitable Temperature: -10~+25℃(14-131F)
  • Suitable Humidity: 0~95%(non-comdensing)
  • Weight: 0.35kg

 

The operation guide of the wireless entrance guard device

 

 

Continuous key operation

 

 

operation name

System password

function

operation

quit

operation results

remark

 

Change system password

#12345

1

88888#88888#

*

The system password is 88888

The system password is five-digit number.

Change the door password

#12345

2

2580(example)

e)

*

The door password is 2580

The door password is four-digit number.

 

Set the opening mode

#12345

3

00 is for password;

01 is just for cards;

02 is for cards or password;

03 is for cards and password.

*

The open mode is the selected mode.

The factory default is 02 mode.

 

Add a card (card number) Add cards

#12345

4

0# card number##

*

The card number is added .All the ID cards which are

The card number is the number that is sprayed on the ID card, the last eight-digit number

Add cards

(continuous read cards)

#12345

4

1# read card #

*

All the ID cards which are continuously read are added

Many cards can be read continuously.

In common use

Remove a card (card number)

#12345

6

0# card number#

*

The card number is removed.

The card number is the number that is sprayed on the ID card,the last eight-digit number

 

Remove cards (continuous read cards)

#12345

6

1# read card #

*

All the ID cards which are continuously read are removed.

Many cards can be read continuously.

In common use

Remove all cards

#12345

8

88# (long whistle)

*

All the user cards are removed.

All user cards can be success fully removed after the buzzer gives a long sound

 

Change door-opening time

#12345

0

02 (double-digit seconds)

*

The door-opening time is change to 2 seconds.

From 01 to 10 seconds

in common use

System initialization

 Open the back cover and remove the battery. Turn the band switch to “ RESEET"

Install the batteries, the buzzer rings five times and the indicator light flashes five times

^ Remove the batteries and turn the band switch to “NORMAL”

The system password is restored to 12345. All other data should not be removed.

 

Remark: The factory password defaults to 12345.After you press #12345, you can hear three consecutive beeps, then the system password has been changed. The system initialization is required to restore.


 

Package:

  • 1x Standalone access control( 4x AAA Batteries is not include
  • 1x Wireless exit switch (Including a 12V/23A battery)
  • 1x Power supply 
  • 1x Strike lock

 

Note: Optional remote control to open the door  

 

詳細を表示する