1K User EM 125Khz extendable data backupable Pin code standalone access control
1K User EM 125Khz extendable data backupable Pin code standalone access control
Product Description
Features:
1. Data backup.you can backup all the enrollments data into a memory IC and then restore to other same devices.
2. Delete/Add cards by master card,
3. Anti-probe the password
4. Add ID cards by the room number,such as can name cards to the controller as "201"(201 is a room number),emember the cards but not its
real number so that you don't have to remember all the cards' number especially when a card lost.
5. Capacity can be extended up to 16K if you need.
6. Reader frequency ID model:125KHz
7.Size:11.5x13.5x2.5 cm
All models support: open the door by password, by card + password , manage the device by master card, data backup and restore by memory IC.
Extendable Optional:Remote control,RFID reader
Card Type:
Card type |
function |
1 |
Common use card |
2 |
Daytime using card,invalid during evening |
3 |
Password attached card,must typing in PW after card reading whenever |
4 |
Password attached during evening.Only card reading is valid during daytime |
Pin Description and wiring diagram:
PIN |
Symbol |
Description |
1 |
+12 V |
DC9-13.8V |
2 |
GND |
Ground |
3 |
NO |
normally open of relays, capacity DC10A/30V |
4 |
COM |
common point of relays, capacity DC10A/30V |
5 |
NC |
normally close of relays, capacity DC10A/30V |
6 |
OPEN |
Connect to open switch |
7 |
DOOR |
Connect to door magnetic sensor |
8 |
ALM |
Alarm bell output port, current load 100mA |
9 |
WG0 |
Wiegand 26 reader data lines (data 0),when a reader extended |
10 |
WG1 |
Wiegand 26 reader data lines (data 1) ,when a reader extended |
11 |
BELL |
doorbell switch, |
Operation manual:
Function |
Key |
Log In |
0*password# .Default administrative password:1234 |
Log off |
0*# |
The functions below should be operated in a Log in status |
|
Change password |
1*newpassword# (password should be 4~6 bits) |
Dispatch user PW |
2*userpassword#(user password should be 4~6 bits) |
Delete user PW |
3*user password# |
Delete all user PWs |
3*9*9# |
Dispatch type 1card |
4*1# card reading(if more cards,can read card continuously) |
Dispatch type 2 card |
4*2# card reading(if more cards,can read card continuously) |
Dispatch type 3 card |
4*3# card reading(if more cards,can read card continuously) |
Dispatch type 4 card |
4*4# card reading(if more cards,can read card continuously) |
Dispatch a remote |
4*5# pressing any key of the remote,the device beep once means OK. |
Delete cards |
5*card number# (card number is a 10 bits printed on card) |
Delete all cards |
5*9*9# (the device beep once means finished) |
Delete a card type |
6*card type# |
Delete all cards&PW |
6*9*9# |
Setup to night mode |
7*password# |
Setup to Normal Open |
8*password#(conveniently for going to work every morning) |
Setup open delay |
9*seconds# (seconds is a 0~99 digit means the duration of delay) |
Setup fault PW times |
10*fault times#(a 2~9 digit,means fault PW entering times,default is 5) |
Setup device suspend time |
11*suspend time#(1~99 ,means 1~99 seconds,default is 10) |
Restore the Manufacture setup |
12*# |
Setup stress PW |
13*stress PW#(4~6 bit) |
The functions below should be operated in a normal status |
|
PW open |
PW # |
Card open |
Card reading,(if a PW needed,press the PW) |
On/Off the night mode |
7*PW # |
On/Off NO status |
8*PW # |
Modify the user PW |
after card reading,press *1* new password# during green light flashing |
Turn on the Stressing Alarm |
Stress PW# |
Turn off the Alarming |
Read any authorized user card |
Others |
|