제품 정보로 건너뛰기
1 8

Rhombus Access Control System

1K User EM 125Khz extendable data backupable Pin code standalone access control

1K User EM 125Khz extendable data backupable Pin code standalone access control

정가 $17.95 USD
정가 할인가 $17.95 USD
할인 품절

Picture 9 of 9



Product Description

Features:

  1. Data backup.you can backup all the enrollments data into a memory IC and then restore to other same devices.
  2. Delete/Add  cards by master card,
  3. Anti-probe the password
  4. Add ID cards by the room number,such as can name cards to the controller as "201"(201 is a room number),emember
        the cards but not its real number so that you don't have to remember all the cards' number especially when a card lost. 
         5.Capacity can be extended up to 16K if you need.
         6. It has 3 models those are compatible with  Mifare1/Hid/EM ,please look the tablet below.

    Parallel all the models:

    model

    FC-198E

    FC-198E16

    Card

    EM

    EM

    User capacity

    1000

    16,000

    All models support:  open the door by  password, by card + password , manage the device by master card, data backup

    and restore by memory IC.

    Extendable Optional:Remote control,RFID reader
     

    Card Type:

    Card type

    function

    1

    Common use card

    2

    Daytime using card,invalid during evening

    3

    Password attached card,must typing in PW after card reading whenever

    4

    Password attached during evening.Only card reading is valid during daytime

     

    Pin Description and wiring diagram:

    PIN

    Symbol

    Description

    1

    +12 V

    DC9-13.8V

    2

    GND

    Ground

    3

    NO

    normally open of relays, capacity DC10A/30V

    4

    COM

    common point of relays, capacity DC10A/30V

    5

    NC

    normally close of relays, capacity DC10A/30V

    6

    OPEN

    Connect to open switch

    7

    DOOR

    Connect to door magnetic sensor

    8

    ALM

    Alarm bell output port, current load 100mA

    9

    WG0

    Wiegand 26 reader data lines (data 0),when a reader extended

    10

    WG1

    Wiegand 26 reader data lines (data 1) ,when a reader extended

    11

    BELL

    doorbell switch,

     

     

    Operation manual:

     

    Function

    Key

    Log In

    0*password# .Default administrative password:1234

    Log off

    0*#

    The functions below should be operated in a Log in status

    Change password

    1*newpassword# (password should be   4~6 bits)

    Dispatch user PW

    2*userpassword#(user password should be 4~6 bits)

    Delete user PW

    3*user password#

    Delete all user PWs

    3*9*9#

    Dispatch type 1card

    4*1# card reading(if more cards,can read card continuously)

    Dispatch type 2 card

    4*2# card reading(if more cards,can read card continuously)

    Dispatch type 3 card

    4*3# card reading(if more cards,can read card continuously)

    Dispatch type 4 card

    4*4# card reading(if more cards,can read card continuously)

    Dispatch a remote

    4*5# pressing any key of the remote,the device beep once means OK.

    Delete cards

    5*card number#  (card number is a 10 bits printed on card)

    Delete all cards

    5*9*9#  (the device beep once means finished)

    Delete a card type

    6*card type#

    Delete all cards&PW

    6*9*9#

    Setup to night mode

    7*password#

    Setup to Normal Open

    8*password#(conveniently for going to work every morning)

    Setup open delay

    9*seconds# (seconds is a 0~99 digit means the duration of delay)

    Setup fault PW times

    10*fault times#(a 2~9 digit,means fault PW entering times,default is 5)

    Setup device suspend time

    11*suspend time#(1~99 ,means 1~99 seconds,default is 10)

    Restore the Manufacture setup

    12*#

    Setup stress PW

    13*stress PW#(4~6 bit)

    The functions below should be operated in a normal status

    PW open

    PW #

    Card open

    Card reading,(if a PW needed,press the PW)

    On/Off the night mode

    7*PW #

    On/Off NO status

    8*PW #

    Modify the user PW

    after card reading,press *1* new password# during green light flashing

    Turn on the Stressing Alarm

    Stress PW#

    Turn off the Alarming

    Read any authorized user card

    Others

    1. press ** anywhen will exit
    2. if the operation is right,the buzzer will sounda long beep,if wrong operation,3 short beep.
    3. Press and hold the reset button for 1 second,one beep,all the setup will be restore to manufacture default.
    4. Press and hold the reset button for 3 seconds,not only restore the manufacture default,but also delete all the data including dispatched cards and PW