Voltage

 

 

Technical Data

Supply voltage: 230V AC is default( If you need 115V AC, 24V DC/AC or 12V DC/AC ,please leave a message to us,

same price for all the voltage versions)
Voltage tolerance AC: +10% / -15%
Voltage tolerance DC: ±15%
Power Consumption: 4.5VA
Output relays: 240V/5A
Operating temperature: -20°C to +65°C
Storage temperature: -40°C to +85°C
Frequency range: 20 kHz to 170 kHz
Reaction time: 100ms
Signal holding time: Unlimited
Sensitivity: Adjustable in 3 increments
Loop inductance: Total loop plus connection wiring: 50μH to 1000μH.
Ideal is 100μH to 300μH
Loop connection wiring: Maximum length 20 meters, twisted at least 20 times per meter
Size of Housing: 78x40x108 mm (L x W x H)

 