Перейти к информации о продукте
1 из 11

Rhombus Access Control System

Touch Keypad 1K user EM4100 125Khz card reader Ext Standalone Access Controller

Touch Keypad 1K user EM4100 125Khz card reader Ext Standalone Access Controller

Обычная цена $22.95 USD
Обычная цена Цена со скидкой $22.95 USD
Распродажа Продано

 

 

Product Description

 

Item  Specification
Card type EM Card
Voltage DC12V
Lock relay DC12V/2A
Environment temperature Working:0-45oC; Storage:-10-55oC
Cards+password  capacity 1000
Pin capacity Public pin :1; Private pin:1000
Reader frequency ID model:125KHz
Card reader distance 5-15CM
Lock interface NO/COM/NC
Exit button 1
doorbell 1
Alarm interface 1
Magnetic 1
External reader 1 Weigand26 interface(only appply to cetain models)
Size 11*9*2cm
Weight 0.25kg

 

Connection diagram


Fast Guide.

Add card

1,add a card:

 press 0 * 1234 # ,and then 4 * 1 # ,read a card ,the unit beeps ,and you can read/add the cards one by one.

2, add a card+password:

0*1234#,and then4*3#,read the cards one by one.

These cards are waiting for password.When these cards were read by the unit,press*1*new password#,now,you have had an unique password for this card.

When you open the door by this card,you should "card+password+#"

Remove the card:

1, to remove a door card: press 0 * 1234 # and press 5 * card number # (card number for the 10-digit number on the card, the card when Jiaka first 10 numbers recorded written on cards to facilitate Subsequent to delete this card), the card swipe can not be directly deleted.

2, remove all door card: press 0 * 1234 #, then 5 * 9 * 9 #

3, delete all passwords and card: press 0 * 1234 # and press 6 * 9 * 9 #

Set other parameters:

a) Set the normally open mode: press 0 * 1234 # and press 8 * password # (4-6 digit password, the default  password is 1234), open the door to keep within the time required in the input 8 * password # to be valid, Cancel Press 8 * Password #.

b)Set the lock delay time: press 0 * 1234 # and press 9 * Time # (default is 5 seconds, can be set to 1-99 seconds).b) Set the alarm duress password: press 0 * 1234 #, then 13 * duress password # (4 to 6 digits password), start by duress PIN #, police rang, please turn off the power lifting power re- electricity can be.

c)detecting the door is not closed for a long time, must be connected to the electric door lock or with feedback, then the green light kept flashing until the door is closed before extinguished. Intrusion alarm buzzer rang non-stop, disarm the alarm function is read legitimate card (valid card to open the door) off.

d) to restore the factory parameters, press 0 * 1234 # and press * # 12, beep sounding cry, the green light becomes off, manage passwords, lock time and other parameters to their default values, then the added card and a password to open the door and so will not be lost.Reset button (RESET): Press the reset button for one second, the buzzer sounding cry, manage password lock time and other parameters to their default values, then the added card and a password to open the door and so will not be lost; press the reset button 3 seconds, that all internal data format will be deleted.

Просмотреть всю информацию